Where does runoff go after it enters a storm drain?

An inlet is a waypoint, not proof of the receiving water. Follow each drainage area through its site discharge point, pipes, ditches or ponds to the water that receives the discharge. A municipal separate storm sewer system (MS4) can carry runoff well beyond the nearest stream.

How to approach it

  1. Use pre- and post-grading contours to sketch flow arrows. Give each site exit a distinct ID. Check low points, overflow paths and temporary diversions; one site can drain in opposite directions.
  2. At each pipe or ditch, record the inlet and outlet IDs and match them to the drainage plan or the storm sewer owner’s asset records. Observe only from a safe, authorized surface location; never enter a structure to complete the trace.
  3. Record the last supported link and the source for it. Mark missing connections as unknown. Ask the system owner for the outfall sheet rather than drawing a straight line to the closest waterbody.
  4. Once the route is supported, check receiving-water names, impairments and designations against official records. Keep the map edition and verification date; a mapped route is not a determination of federal jurisdiction.

Worked example

The nearest creek lies west of a parking lot. The city asset map shows inlet I-4 flows east through pipe P-6 to outfall O-12 at a different brook. Label I-4 and O-12 separately and save the map reference. If the sheet ends at P-6, record “receiving water unknown” until the next link is found.

Next step

Complete a drainage worksheet for each site exit and send the unresolved asset IDs to the storm sewer owner.

Next on this task

Use the worksheet