How to approach it
- Start with the permit or inventory instructions: they may specify a test, material balance, or factor. Compare any candidate factor with source-specific performance data.
- Match the pollutant, process, fuel, operating load, measurement boundary, and control status. Record the table, version, units and limitations. Do not apply a removal percentage to a factor already measured after control.
- Cancel the activity units explicitly. If a permit decision depends on a maximum rather than an average, ask what maximum-rate evidence is acceptable.
Worked example
An illustrative uncontrolled factor of 0.08 lb/MMBtu times 15 MMBtu/h yields 1.2 lb/h. Multiplying that factor by 15 cubic feet/h would leave mismatched units; obtain the fuel heating value first. The example factor is not a recommended value.
Next step
Attach the exact factor entry and the activity data, not just a link to the AP-42 homepage.